Add to Cart
Double Display LCD And LED Electric Power Belt Weigher Indicator , Standard Modbus With RS232
Technical Specification
² CMC GB/T 7724-2008PRC National Standard.
² OMIL R50:1997International Recommendation.
² Accuracy Grade: 0.5.
² Accuracy of Flow Control: 0.5%~1.0%.
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 【ESC】 | Enter Main Menu. Exit. |
【ENT】 | Enter. Save. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 | Cursor shifts up. Display the previous interface or option. Digit input: +1. |
【▼】 | Cursor shifts down. Display the next interface or option. Digit input: -1. |
Quick Operation | |
【MENU】* (【LOCK】) |
|
【◄】 (【ADJ+】) | Control Current +1mA. |
【►】 (【ADJ-】) | Control Current -1mA. |
【◄】* (【AUTO】) | ‘Manual/Auto’ Control Mode Selection. |
【►】* (【EXT】) | ‘Internal/External’ Flow Set Mode Selection. |
【PRINT】 (【ENT】) | Print. |
Model Panel-mounting Installation
Ration Flow Auto-Feeding System
Technical Specifications:
Power Supply: AC220V±15%, 50/60Hz, Max. 10W.
Loadcell Excitation Voltage/Current: DC10V/250mA.
8 Loadcells[350Ω] connectable.
Weighing Signal Input Range: 0~25mV.
Speed Sensor Excitation Voltage/Current: DC12V/100mA.
Speed Signal Input Range: 0.5~3000Hz.
COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.
COM2: RS232.
Connect Host IPC, Remote Display, Printer&Wireless Module.
Optional 4~20mA Analog Output [AO] Module by COM1.
Outline Size [W×H×D]: 235.5 × 227.5 × 119.5 mm.
Operating Temperature: -25℃~+45℃.
Protection Level: IP65.
Accuracy Grade: 0.5.