Alarm Signs
Sign | Alarm Cause | Solution |
Err1 | RAM Failure. | Replace the chip RAM. |
Err2.1 Err2.2 | EEPROM Failure. | Replace the chip EEPROM. |
Err3 | Signal reversed or not connected. | Connect the loadcell correctly. |
Err4 | ADC Failure. | Replace the ADC module. |
oV-Ad | Over ADC Range. | Weighing signal exceeds A/D conversion range. 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
oL | Overload Alarm. | Gross Weight > (Scale Capacity + 9 × Scale Division). 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
HI | Gross Weight Upper Limit Alarm. | Refer to parameter [210] ‘Gross Weight Upper Limit’. |
OV-PAUSE | Pause for Up Tolerance Alarm. | Press DI button ‘Start/Clear Alarm’ to recover running. |
dn-PAUSE | Pause for Low Tolerance Alarm. | It’s allowed to do ‘Manual Dribble Re-feed’. Press DI button ‘Start/Clear Alarm’ to recover running. |
bAt-End | Alarm or Auto-stop for ‘Batch Count Target Finished’ or ‘Batch Weight Target Finished’. | Refer to parameter [208] ‘Batch Count Target’, [209] ‘Batch Weight Target’ and [301] ‘Batch Target Control ’. Clear Screen to clear the message. |
LASt-bAt | Last Batch. | The message will disappear after the present batch finished. |
oV-tr | Not meet the condition of Maunal Tare. | When Gross Weight is at the state with negative value display, overload alarm or dynamic variation, ‘Manual Tare’ will be invalid. |
Over ‘Auto Tare Range’. | Refer to parameter [131] ‘Auto Tare Range’. | |
oV-nZ | Over ‘Manual/Auto Zero Limit’. | Refer to parameter [123] ‘Manual/Auto Zero Limit’. |
AuZr | Auto Zero. | Refer to parameter [302] ‘Auto Zero Cycle Interval’. |
Autr | Auto Tare. | Refer to parameter [303] ‘Auto Tare Cycle Interval’. |
HEAt | Preheating Time Countdown [min.sec]. | Refer to parameter [128] ‘Zero Upon Power Up’, [129] ‘Power Up Zero Time’ and [130] ‘Power Up Zero Limit’. Wait for the preheating time over or press any key to exit. |
oV-Zr | Over ‘Power Up Zero Limit’. | |
Prt-undEF | Print port is not defined. | Refer to ‘Communication Parameters’. |