Add to Cart
Touch Screen Bagging Controllers For 5-50kg Rice/Sugar Packaging Machinery
Main Features:
1. Suitable for Ration Packing Scale with optional Hopper-weighing Mode, Bag-weighing Mode and Loss-in-weight Mode.
2. EMC design with high anti-jamming capability, suitable for industrial environment.
3. Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
4. 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
5. Loadcell Interface
l Max. Connection Quantity: 16 Loadcells (350Ω).
l 24-bit High-precision and high-speed ∑-A/D conversion module with 1/1,000,000 internal resolution and samplingfrequency 800Hz.
l Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strongvibration on the load receptor, and the rapid response capability when the weight signal changes.
² I/O Interface
l 9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].
l Optional ‘High/Medium/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
l 2 Definable analog signal AOs[0~10V] for weight signal output or ‘High/Medium/Low Speed Feed’ control.
Data Display & Quick Setting
Name | Description | Authorization |
Biggest Digits | Real-time Weight [Weight Unit]. | |
[HI] | Weight Upper Limit Alarm [Bucket Scale / Bag Scale]. | |
[MAT_HI] | Material Level High Limit Alarm [Bucket Scale / Bag Scale]. | |
[MAT_LO] | Material Level Low Limit Alarm [Bucket Scale / Bag Scale]. | |
[GROSS] | Material Gross Weight in Weighing Bucket [Loss-in-weight Scale]. | |
[HI] | Gross Weight Upper Limit Alarm [Loss-in-weight Scale]. | |
[LO] | Gross Weight Lower Limit Alarm [Loss-in-weight Scale]. | |
[Cycles] | Batch Count. | |
[Final] | Final Feeding Weight. | |
[▲]/[HI] | Up Tolerance Alarm. | |
[▼]/[LO] | Low Tolerance Alarm. | |
[TOTAL] | Totalized Weight. | |
[Date&Time] | Date&Time. | |
[RUN] | Auto Running state. | |
[PAUSE] | Pause state. | |
[P_SW] | DI switch ‘Dumping Gate Closed in Place’ turned on. | |
[ZERO] | Weight ≤ Non-load Zero Range. | |
[STAB] | Weight is stable. | |
[FED] | Feeding Ended. | |
[OVLD] | Overload Alarm. | |
[FIN] | Batch Target Finished. | |
[LABEL]/[GAS]/ [SEW]/[CUT] | In the process of ‘Label on Bag’ / ‘Fill Gas into Bag’ / Bag-sewing / Thread-cutting. | |
[Recipe] | ‘Working Recipe No.’ Setting. | All Users |
Recipe Parameters Setting. | Engineer | |
Flow Parameters Setting. | ||
[Target] | ‘Target Weight’ Setting. | All Users |
[Bulk] | Bulk Lead Weight. | |
[Med] | Medium Lead Weight. | |
[Inflight] | Dribble Inflight Weight. | |
| ||
[Mode] | 1-Bucket Scale / 1-Bag Scale / Loss-in-weight Scale. Refer to Parameter [300] ‘Application Mode’. | Engineer Administrator |
[Mat. Au-supply DI] | ‘Material Auto-supply Permission’ DI turns ON/OFF. | |
[Cycle Set] | Batch Count Target. | |
[Total Set]] | Batch Weight Target. | |
[cpm] | Cycle Speed [Cycles/min]. |
Error Messages
Message | Alarm Cause | Solution |
RAM Fault | The chip RAM is damaged. | Replace the chip RAM. |
EEPROM Fault | The chip EEPROM is damaged. | Replace the chip EEPROM. |
Parameter Error | The chip EEPROM is damaged. | Replace the chip EEPROM. |
Weighing Signal Error | Weighing signal reversed or not connected. | Connect the loadcell correctly. |
ADC Fault | The chip ADC is damaged. | Replace the ADC module. |
Over ADC Range | Weighing signal exceeds A/D conversion range. | 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
Overload Alarm | Weight > (Scale Capacity + 9 × Scale Division). | 1. Check if the set value of parameter [102] ‘Scale Capacity’ is reasonable. 2. Check if the loadcell is connected. 3. Check if the capacity of loadcell is too small. 4. Check if the loading weight is too big. |
Internal Data-bus Fault | Please contact manufacturer. |