Add to Cart
DC24V High Accuracy Of flow control Loadcell Belt Scale Weighing Indicator With 3 DI and 4 DO
Main Features:
1 ‘Flow Set’ Analog Input [AI]: 4~20mA, 0.05%FS.
2. COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.
3. COM2: RS232.
4. Connect Host IPC, Remote Display, Printer&Wireless Module.
5. Outline Size [W×H×D]: 164 × 86 × 193 mm.
6. Panel Cut-out Size [W×H]: 153 × 77 mm.
7. Accuracy of Flow Control: 0.5%~1.0%.
Main Menu | Second Menu | Description |
F1 Setting | 1 Scale[Basic] | Basic scale parameters setting. |
1+Scale[Extra] | Extra scale parameters setting. | |
2 Control[Basic] | Basic feeding control parameters setting. | |
2+Control[Extra] | Extra feeding and batching control parameters setting. | |
3 Flow | Flow parameters setting. | |
4 Speed | Speed parameters setting. | |
5 Load | Load parameters setting. | |
6 Save/Print | Weight record parameters setting. | |
7 Comm. Port | Communication port parameters setting. | |
8 I/O | Input&output parameters setting. | |
9 Display | Display and operation interface parameters setting. | |
10 Date/Time | Date/Time parameters setting. | |
F2 Calibration | 1 Zero Cal. | Zero Calibration without loading for correcting Zero Value. |
2 Span Cal. Dyn. | Dynamic Span Calibration with loading measured materials or Poise Weights for correcting Span Coefficient. | |
3 Span Cal.Stat1 | Static Span Calibration with a measured chain weight as a continuous and steady load on the running belt weigher for correcting Span Coefficient. | |
4 Span Cal.Stat2 | Static Span Calibration with a measured Hanging Weight as a steady load on the running belt weigher for correcting Span Coefficient. | |
5 Span Cor. Seg. | Segmenting Span Correction. After doing Dynamic or Static Span Calibration, further corrections for 3 [AD Value: 0~60000] linear segments are optional for correcting Correction Coefficient 1~3. | |
6 Speed Cal. | Speed Coefficient Calibration. Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Speed Coefficient. | |
7 Length Cal. | Belt Length Calibration. Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Belt Length. |
Main Menu | Second Menu | Description |
F3 Weight Record | Query and print Weight Records. | |
F4 Data Clearing | 1 Clear Screen | Clear Totalized Weight and Totalized Weight Pulse Count. But Totalized Weight of Current Shift will not be cleared, so this operation has no effect on recording of weight per shift. |
2 Clear Weight | Clear Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift. The cleared value of Totalized Weight of Current Shift will not be recorded. | |
3 Clear Records | Clear History Records of Totalized Weight. But Current Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift will not be cleared. | |
F5 Security | 1 Auto-locking | If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the controller will lock the keypad and return to ‘Main Display Interface’ automatically. |
2 Key-locking | Locking keypad. | |
3 Key-unlocking | Unlocking keypad. | |
4 Password Set | Exfactory Password: 000001. | |
5 RAM Reset | Restore to factory defaults. | |
F6 Factory Adj. | Special for manufacturer. | |
F7 Product Info. | Only for query. | |
1 Version No. | Version No. | |
2 Serial No. | Serial No. | |
3 Exfactory Date | Exfactory Date. | |
4 Audit Counter | Audit Trail Counter [0~99999999] for Scale parameter’s modification. | |
5 Auth. Code | Authorization Code. |
Delivery