Add to Cart
1-4 Channels Force Measuring Controller For Positive&Negative Direction Peak Value Detection
Main Features:
Technical Specification:
Power Supply | DC24V±20%,Max.10w. |
Display | HMI |
Sampling Frequency | 600Hz |
A/D Convert | 24-bit |
LAN | Optional Ethernet |
USB1 | Connect mouse, software download, data backup |
Max. Connection number of Loadcell | 16Loadcells (350Ω) |
DI | 7 Normally Open Switch Inputs |
DO | 18 Normally Open Transistor Switch Outputs |
AO | 4Analog Signal Output: 4~20mA. |
Operating Temperature | -25℃~+45℃ |
Verification Accuracy | 0.02% |
Batching Accuracy | 0.2%~0.5% |
Main Operation Interface for APP1 Single-scale Mode
Name | Operation | State Indicator | Authorization |
【Start】 【Stop】 | Start/Stop Peak Detection Process. | Green: Running state. Grey: Stop state. | All Users |
【Menu】 | Enter Main Menu. | ||
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. | |
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
[Recipe] | ‘Working Recipe No.’ Setting. | ||
【Clear】 | Clear Screen. | ||
【Alarm】 | Clear Alarm. | ||
【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | ||
【Curve】 | ‘Curve Window Property’ Setting. | Engineer Administrator | |
【Mode】 | ‘Working Mode’ Setting. Refer ‘6.3.3 Working Mode Parameters’. |
Data Display & Quick Setting
Name | Description | Authorization |
Green Digits | Real-time Force Value. | |
Curve Window | Display in Peak Detection Process: Green Real-time Force Value Curve, Red Positive Direction High/Low Limit Straight Line and Pink Negative Direction High/Low Limit Straight Line. | |
【Zoom】Operation. | All Users | |
[#1/#2/#3/#4] | Channel No.. | |
[A/B/C/D] | Channel Name. | |
[RF] | Reference Value. | |
[CP] | Comparison Value. CP=(Real-time Force Value-Reference Value)/ Reference Value × 100% | |
[HI] | High Limit Value. | |
[LO] | Low Limit Value. | |
[NV] | Negative Direction Peak Value. | |
[PV] | Positive Direction Peak Value. | |
[▲] | High Limit Alarm. | |
[▼] | Low Limit Alarm. | |
[Date&Time] | Date&Time. |
1-4 Channels Force Measuring Controller For Positive&Negative Direction Peak Value Detection
Outline Size
Installation Mode