VFD Ration Batching Controller Digtal Weight Indicator For 5-Material Ration Batching Scale
Main Features:
- Suitable for Ration Batching Scale with 5-Material&2-Speed Feeding [Single-Scale Mode].
- EMC design with high anti-jamming capability, suitable for industrial environment.
- 32-bit ARM CPU with 72MHz clock & higher arithmetic speed.
- 6+10 green VFD digital tubes for English character and digit display.
- 8-key English keypad.
- Menu&Shortcut mode operation with key tone.
- 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 400Hz.
- Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
- Max. Connection Quantity: 8 Loadcells (350Ω).
- Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
- Optional Data Calibration function.
- Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
- 7 Normally open switch inputs [DI] and 12 normally open transistor switch outputs [DO].
- Optional ‘High/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
- 1 Optional and definable analog signal AO[4~20mA] for weight signal output or ‘High/Low Speed Feed’ control.Optional ‘Fall Value Auto Correction’ function.
- 10 Recipes for batching control.
- Optional ‘Fall Value Auto Correction’ function.
- Optional ‘Auto Pause for Deviation Alarm’, ‘Auto Pause for Gross Weight Upper Limit Alarm’ and ‘Manual Pause’ functions.
- Optional ‘Target Batch Control’ function [With Target Batch Count finished, the batching process will stop automatically].
- ‘Batching Process Power-off Protection’ function available.
- 2 Optional communication ports for connecting Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
- The present Batch Record can be printed automatically and manually.
- 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
- With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Pictures




Technical Specification
- CMC GB/T 7724-2008PRC National Standard.
- OMIL R76: 2006International Recommendation.
- Accuracy Grade: III.
- Verification Accuracy: 0.02%.
- Static Weighing Accuracy: 0.2%~0.5%.
- Batching Accuracy: 0.2%~0.5%.
- 6+10 Green VFD digital tubes for English character and digit display.
- Weight Display Range: -99,999~+999,999.
- Scale Capacity: Setting Range 1~999,999.
- Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
- Display Resolution: 1/100,000.
- Weight Unit: Optional kg, t, g, none.
- Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
- Display Refreshing Time: Setting Range 0.01~1.00s.
- 8-key English keypad.
- Menu&Shortcut mode operation with key tone.
- Excitation Voltage/Max. Current: DC10V/250mA [8-350Ω loadcells].
- Signal Input Range: 0~25mV.
- Output Sensitivity of Loadcell: 1.0~2.5mV/V.
- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
- Sampling Frequency: 400Hz.
- Special anti-vibration digital filtering algorithm.
- Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
- Gain Drift: ±5ppm/℃.
- Non-linearity: 0.005%FS.
- Switch&Analog Signal Interface
- 7 Normally Open Switch Inputs [DI].
- 12 Normally Open Transistor Switch Outputs [DO]: DC24V, 500mA.
- 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.
- Digital Communication Interface
- COM1: RS232.
- COM2 Optional: RS232/RS485/RS422/Profibus-DP/Ethernet modules.
- Connectable: Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
- The present Batch Record can be printed automatically and manually.
- 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
- Optional Operating Voltage
- Operating Voltage 1: DC24V±20%.
- Operating Voltage 2: AC85~264V, 50/60Hz.
- Operating Voltage 3: AC220V±15%, 50/60Hz.
- Free to configure one of them.
- Max. Power Consumption: 10W.
- Outline Size
- Model Panel-mounting: 164×82×188mm [W×H×D].
- Model Explosion-proof: 340×390×205mm [W×H×D].
- Model Panel-mounting: 153×77mm [W×H].
- Operating Temperature: -25℃ to +45℃.
- Storage Temperature: -30℃ to +60℃.
- Relative Humidity: Max. 85%RH.
- Application Environment of Model Explosion-proof
- Explosion gas environment: Zone 1&2.
- Classes of explosion gas mixture: IIA, IIB.
- Temperature grades of explosion gas mixture: T1~T6.
- Ex-mark: Ex d IIB T6 Gb.
- Front Panel of Model Panel-mounting: IP65.
- Model Explosion-proof: IP65.
- Model Panel-mounting: Approx. 1.6kg.
- Model Explosion-proof: Approx. 19.2kg.
Model Panel-mounting Operation Interface

Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation |
Key Name | Description |
【MENU】 | Enter Main Menu / Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 | Display the previous interface or option. Digit input: +1. |
【▼】 | Display the next interface or option. Digit input: -1. |
Quick Operation |
【Ñ】 * | - Key-locking.
- Key-unlocking.
|
【SET】 | M1~M5 Target Values setting. |
【G/N】 | Gross Weight / Net Weight display switch. |
【→C←】 【CAL】 * | Load Calibration. |
【→0←】 【ZERO】 * | - [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
- [≡ZEro≡] Zero Fine Adjustment without Power-down Protection and without Clearing Tare Weight.
- The controller will switch to Gross Weight display.
|
【→T←】 【TARE】 * | - [≡tArE≡]: Manual Tare without Power-down Protection.
- [-PStr-]: Preset Tare Weight with Power-down Protection.
- [-rStr-]: Clear Tare Weight with Power-down Protection.
- The controller will switch to Net Weight display.
|
【,】* | Record Query. |
【/】* | Clear Screen: Clear the display value of Tatal Feeding Weight, Totalized Weight and Batch Count. |
【‡】* | Time display and setting. |
【±】 | ‘+’/‘-’ switch. |
【6】 | Main Display Interface: - [bAt.tAb]: Print Present Batch Record.
- [tot.tAb]: Print Totalizing Report.
- [SEt.tAb]: Print Present Recipe.
Record Query state: Print Historical Batch Record. |
【ENT】 | Pause State: - [Cont]: Recover Running.
- [StoP]: Stop.
|
*: Keep the key pressed for 2 seconds.
State Indication
Sign | Description |
[GROSS] | Gross Weight display. |
[NET] | Net Weight display. |
[LOCK] | ON: Key-locked. OFF: Key-unlocked. |
[◣◢] | Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’. |
[→0←] | The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’. |
[kg/t/g] | Weight unit. |
[ NUM] | Material No. display. |
[ PCS] | Batch Count display. |
[TOT] | Totalized Weight display. Total Feeding Weight display. |
[SET] | Target Value display. Parameter setting state. |
[RUN] | ON: Running state. Blinking: Pause state. OFF: Stop or Calibrating state. |
[ZERO] | Net Weight ≤ Non-load Zero Range. |
[NZ] | It’s allowed to do Zero Fine Adjustment. |
[SP1] | High-speed Feeding. |
[SP3] | Low-speed Feeding. |
[FILL] | Stop state: Weight value is increasing. |
Running state: It’s in the feeding process. |
[COMP] | ON: It’s doing comparation between Feeding Weight and Target Value. OFF: It turns off in Comparing-prohibited Time. |
[DEV] | Positive/Negative Deviation Alarm. |
[FALL] | ON: Fall Value Auto Correction function is open. |
[DISC] | Stop state: Weight value is reducing. |
Running state: It’s in the dumping process. |
[HH] | Gross Weight Upper Limit Alarm. |
Model Panel-mounting Installation

Model AC85~264V/AC220V Terminal

System Diagram for M1~M5 Ration Batching System